10 Units of SCB12-800kVA Dry-Type Transformers for a Specialist Cancer Hospital in the UK

 

Project Overview

HBTP supplied 10 units of SCB12-800/10 transformers for a specialist cancer treatment and research center in London, United Kingdom. The project represents a significant deployment in the specialist healthcare sector, requiring transformers engineered for reliable operation under demanding conditions.

Project Background

This specialist cancer center houses advanced medical imaging equipment including MRI, CT, and linear accelerators for radiation therapy. These devices require high-quality power with minimal harmonic distortion and voltage fluctuations to ensure accurate imaging and treatment delivery.

Customer Requirements

800kVA dry-type transformers, medical-grade power quality specifications, low noise (≤52dB(A)) for patient areas, design for non-linear loads from medical imaging equipment, compliance with BS EN 60076-11 and UK HTM (Health Technical Memorandum) standards.

Our Solution

HBTP supplied its SCB12-series transformers, engineered specifically for specialist healthcare applications. The high-quality CRGO silicon steel core with step-lap mitered joints minimizes no-load losses, while copper windings provide enhanced short-circuit withstand capability and long service life.

Parameter Specification
Model SCB12-800/10
Capacity per Unit 800 kVA
Voltage Ratio 10 / 0.4 kV
Cooling ANAF
Efficiency SCB12
Standard BS EN 60076-11
Power Quality Medical Grade
Harmonics Linear Loads (MRI/CT)
Noise ≤ 52 dB(A)

Quality & Testing

All units passed harmonic load testing to verify performance with non-linear medical equipment loads. Sound level testing confirmed ≤52dB(A) for installation near patient care areas. Medical-grade isolation specifications were verified.

Delivery & Installation

The 10 units were delivered in sequenced batches to minimize disruption to the hospital's ongoing operations during the phased expansion. HBTP provided technical support for coordination with medical equipment suppliers.

10
Units Supplied
≤52dB
Ultra-Low Noise
Medical
Grade Power

Project Outcomes

All 10 transformers were successfully energized and are operating at rated capacity. The project was completed on schedule, and the customer has reported excellent performance with no unplanned outages attributed to transformer equipment. HBTP's reliable power distribution solution has contributed to the project's overall success and operational efficiency.